EtherCom

The Connectivity Connection

The Connectivity Connection
510.440.0242
info@ethercom.com
  • Home
  • About Us
  • Products
    • Ethernet Transceivers
      • E8PFO
      • EB02
      • EFL01
      • EB05
      • ETP910N
    • Fault Tolerant Transceivers
      • EFTS1025
      • EFTT1003
      • EFTT1039
      • ERMFTT1008
      • ERMGT350
      • ETP1010
      • ETP1020N
    • Hubs & Repeaters
      • EC200, EC400, EC800 Series
      • EC880 Series
      • EHB44 and EHB46
      • EHB89 Series
      • EHB162S and EHB163S
    • Ethernet Switches
      • ERS6FT2TX-GTX
      • ES6T2F
      • ESG5
      • ESG6T2F
      • ESG9
      • ESG51
      • ESG81
      • ESG500
      • ESM41
      • ESM81
      • ESM500
      • ESM900
      • ERSG9 Series
    • Ethernet Media Converters
      • EFM12N
      • EFM14
      • EGM102
      • EMB11
      • EMC01
      • EMC01N
      • EMC02N
      • EMC03
    • Rack Mount Chassis
      • ERM02
      • ERM12N
      • ERM14
      • ERM21C
      • ERMC01N
      • ERMB11
      • ERMFTT1008
      • ERMG102
      • ERMGFT350
  • Technical Resources
    • Glossary
    • Data Sheets / User Manuals
    • EtherCom Limited Warranty
  • News
  • Contact Us

EMC01N

10BaseT to 10Base2 Media Converter

EMC01N Media Converter

Documentation

  • EMC01N Datasheet PDF

Product Description
The EMC01N is a wall-mount, compact, cost-effective means for adapting existing Ethernet cabling to configure to network requirement changes. The IEEE 802.3 compatible EMC01N converts ThinNet signals to UTP (unshielded twisted pair), and vice-versa. The EMC01N is a highly robust design and is packaged in a rugged metal enclosure to ensure durability and reliability.

Media Interface

UTP (10BaseT): RJ45 Modular 8-Pin female connector, with MDI/MDIX feature
BNC (10 Base2): RG-58 ThinNet

Installation
Special consideration must be given to maximum segment lengths on each side of the EMC01N. It is recommended that IEEE 802.3 specifications for segment distances be adhered to: UTP (10BaseT) = 100m (300 ft.) ThinNet (10Base2) = 185m (555 ft.)

UTP Crossover Capability
There are some applications in which the UTP segment may or may not be connected to the repeater.
To provide maximum installation flexibility, the EMC01N features a UTP crossover switch that eliminates the need for a specially configured UTP crossover cable. This allows a repeater or non-repeater decisive
to be attached to the UTP segment side. The slide switch is located next to the RJ45 connector and is accessible without opening the case.

Technical Specifications

Network Standards Ethernet IEEE 802.3
Speed 10 Mbps
Power 110 – 220 VAC to 12 VDC @ 1 A
External power adaptor
LEDs Total 5:
Link, Transmit, Receive, Collision & Power
Weight 0.4 lb. 182.0 g.
Dimensions 4.5โ€ x 2.1โ€œ x 1.0โ€
(11.4 cm x 5.4 cm x 2.5 cm)
Environmental Operating Temperature: 32 to 122F (0 to 50 C)
Storage Temperature: -4 to 140F (-20 to 60 C)
Relative Humidity: 5% to 80% (non-condensing)
Switches 1 Cross over – for RJ45 Connector
Connectors 1 Fully Shielded RJ45 & 1 BNC
Cabling UTP maximum cable distance 100 meters
Thin-net maximum cable distance 185 meters
EMI & Safety FCC Class A, CE.
Warranty 5 years